View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 355 | RackTables | default | public | 2010-07-20 15:24 | 2011-02-15 08:41 |
| Reporter | Assigned To | ||||
| Priority | normal | Severity | feature | Reproducibility | N/A |
| Status | closed | Resolution | won't fix | ||
| Product Version | 0.18.4 | ||||
| Summary | 355: unhandy port types for patch panels | ||||
| Description | As patch panels are passive, ports of patch panels (esp. the future "linked" ones) should not be of "active" typed (1000BaseTX et al) but of the type of cable/connector that is used; e.g. "SC/APC9°-duplex OS2", "LC/PC-duplex OM4" or "RJ45 Cat7/SSTP". The port compatability matrix can then be derived from relevant standards (perhaps even regarding the internal link-length of the linked patchpanels? e.g. 10GBaseSR works on 100m of OM3 but only 55m of OM2) | ||||
| Tags | No tags attached. | ||||
| Excuse me, but there are no resources to spend on this, so the software will remain limited in this regard. | |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2010-07-20 15:24 |
|
New Issue | |
| 2010-09-02 15:27 | infrastation | Note Added: 0000128 | |
| 2010-09-02 15:27 | infrastation | Status | new => closed |
| 2010-09-02 15:27 | infrastation | Resolution | open => won't fix |
| 2011-02-15 08:41 | infrastation | Relationship added | duplicate of 333 |