View Issue Details

IDProjectCategoryView StatusLast Update
355RackTablesdefaultpublic2011-02-15 08:41
Reporteruser165Assigned To 
PrioritynormalSeverityfeatureReproducibilityN/A
Status closedResolutionwon't fix 
Product Version0.18.4 
Summary355: unhandy port types for patch panels
DescriptionAs patch panels are passive, ports of patch panels (esp. the future "linked" ones) should not be of "active" typed (1000BaseTX et al) but of the type of cable/connector that is used; e.g. "SC/APC9°-duplex OS2", "LC/PC-duplex OM4" or "RJ45 Cat7/SSTP".
The port compatability matrix can then be derived from relevant standards (perhaps even regarding the internal link-length of the linked patchpanels? e.g. 10GBaseSR works on 100m of OM3 but only 55m of OM2)
TagsNo tags attached.

Relationships

duplicate of 333 assignedadoom42 Add sql to /install/init.structure.sql to create PatchPanelMap table 

Activities

infrastation

infrastation

2010-09-02 15:27

administrator   ~0000128

Excuse me, but there are no resources to spend on this, so the software will remain limited in this regard.

Issue History

Date Modified Username Field Change
2010-07-20 15:24 user165 New Issue
2010-09-02 15:27 infrastation Note Added: 0000128
2010-09-02 15:27 infrastation Status new => closed
2010-09-02 15:27 infrastation Resolution open => won't fix
2011-02-15 08:41 infrastation Relationship added duplicate of 333